Welcome to SHJ Electronic Co.,Ltd
.: Data Acquisition Modules
Ethernet Modules
|
|
S6512 : 812-CH 0- 5V,0 -10V,4 - 20mA analog inputs,3-CH isolated DI, 8-CH isolated open-collector outputs , 8-CH 0-10V analog output module ,Ethernet/RS485,Modbus TCPIP/Modbus protocol |
S6133 : 2 -CH 0- 5V,0 -10V,4 - 20mA analog inputs,12-CH isolated DI, 2-CH TYPE-C relay output,60VDC power supply,Ethernet/RS485,Modbus TCPIP/Modbus protocol |
- Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- The channel number is configurable, can be set up from 1 channel through 12 channels, for analog input improve sample rate for small count input
- Relay output support normal open
- Standard ModBus TCPIP protocol,easy work with PLC
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- Can update your firmware via ISP through RS485 network, can provide any hex file to help you finish some logic control
- DIN support available
|
- Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- The channel number is configurable, can be set up from 1 channel through 2 channels, for analog input and set up from 1 to 12 for digital input, improve sample rate for small count input
- Isolated digital inputs can be configured as counter input, total 32 bits,1000Hz
- Relay output support normal open and normal close
- Max 60VDC power input
- Isolated 5V and isolated 12V power output, both are 2W power
- Standard ModBus TCPIP protocol,easy work with PLC
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- Can update your firmware via ISP through RS485 network, can provide any hex file to help you finish some logic control
- DIN support available
|
Technical_S6512.zip |
Technical_S6133.zip |
Price: $109
|
Price: $145 |
|
|
S6135: Ethernet 8 -CH 0- 5V,0 -10V,4 - 20mA, NTC 10K thermistor analog inputs,11-CH isolated DI, 8-CH 0-10V analog output module ,Ethernet/RS485,Modbus TCPIP/Modbus protocol |
S6312: Ethernet 12 channels isolated digital input,32-bit counter, 12 channesl normal open relay output,Modbus/TCPIP and Modbus protocol |
- Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- The channel number is configurable, can be set up from 1 channel through 8 channels, for analog input and set up from 1 to 3 for digital input, improve sample rate for small count input
- 8 channels 0-10V analog output with high accurate reference chip
- 11 channels Isolated digital inputs can be configured as counter input, total 32 bits,1000Hz
- Standard ModBus TCPIP protocol,easy work with PLC
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- White and black encloure available ,DIN rail
|
- 12 channels Isolated digital inputs can be configured as counter input, total 32 bits,1000Hz
- Total 12 channels relay output ,normal open
- Standard ModBus TCPIP protocol,easy work with PLC
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- White and black encloure available ,DIN rail
|
Technical_S6135.zip |
Technical_S6312.zip |
Price: $139 |
Price: $109 |
|
|
S5134 : 8 -CH 0- 5V,0 -10V,4 - 20mA analog inputs,3-CH isolated DI, 8-CH isolated open-collector outputs , 8-CH 0-10V analog output module ,Ethernet/RS485,Modbus TCPIP/Modbus protocol |
S5138 : 8 -CH 0- 5V,0 -10V,4 - 20mA analog inputs,6-CH isolated DI, 16-CH isolated open-collector outputs ,,Ethernet/RS485,Modbus TCPIP/Modbus protocol |
- Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- The channel number is configurable, can be set up from 1 channel through 8 channels, for analog input and set up from 1 to 3 for digital input, improve sample rate for small count input
- 8 channels 0-10V analog output with high accurate reference chip
- 3 channels Isolated digital inputs can be configured as counter input, total 32 bits,1000Hz
- Total 8 channels isolated open-collector output
- Standard ModBus TCPIP protocol,easy work with PLC
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- White and black encloure available ,DIN rail
|
- Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- The channel number is configurable, can be set up from 1 channel through 8 channels, for analog input and set up from 1 to 6 for digital input, improve sample rate for small count input
- 6 channels Isolated digital inputs can be configured as counter input, total 32 bits,1000Hz
- Total 16 channels isolated open-collector output
- Standard ModBus TCPIP protocol,easy work with PLC
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- White and black encloure available ,DIN rail
|
Technical_S5134.zip |
Technical_S5138.zip |
Price: $145
|
Price: $115
|
|
|
S6116: Ethernet 16 chananels analog input modules 0-5V, 0-10V, 4-20mA, dry contact, 10K NTC thermistor inputs ,12-bit ADCs, Modbus/TCPIP and Modbus protocol |
S6216: Ethernet 16 chananels analog input modules 0-5V, 0-10V, 4-20mA, dry contact, 10K NTC thermistor inputs ,16-bit ADCs, Modbus/TCPIP and Modbus protocol |
- Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V, 0-5V, 4-20mA, NTC 10K thermistor and dry contact
- The channel number is configurable, can be set up from one channel through eight channels, improve sample rate for small count analog input
- A lot of spare FLASH can be used to store user’s parameters
- Standard MODBUS/TCPIP protocol for Ethernet and standard MODBUS protocol for RS485
- DIN support available
|
- Surge-protected analog inputs with 16-bit resolution and 100k sample speed
- Input can be any combination of 0-10V, 0-5V, 4-20mA, NTC 10K thermistor and dry contact
- The channel number is configurable, can be set up from one channel through eight channels, improve sample rate for small count analog input
- A lot of spare FLASH can be used to store user’s parameters
- Standard MODBUS/TCPIP protocol for Ethernet and standard MODBUS protocol for RS232/RS485
- DIN support available
|
Price: $80
|
Price: $125
|
Technical_S6116.zip |
Technical_S6216.zip |
|
|
S6301: Ethernet 8 channels isoalted digital input and 8 channels isolated digital output module, Modbus/TCPIP and Modbus protocol |
S6302: Ethernet 16 channels dry/wet isolation digital input modules, 0-36VDC common anode input, Modbus/TCPIP protocol and Modbus protocol |
- Industry Ethernet with MODBUS/TCPIP
- RS232/RS485 with MODBUS protocol to configure the module
- Isolated digital inputs can be configured as counter input, total 32 bits, 5000Hz
- Can measure frequency from 0 to 1000Hz, the resolution is 0.1Hz
- Accept reed and hall sensor output from water meter or other meters
- Static and lightning protection for each input
- The input channel number is configurable, can be set up from 1 channel through 8 channels, improve frequency for small count input
- Isolated open-collector output can drive power relay directly
- A lot of spare FLASH can be used to store user’s parameters
- DIN support available
|
- Industry Ethernet with MODBUS/TCPIP
- RS232 / RS485 with MODBUS protocol to configure the module
- Isolated digital inputs can be configured as counter input, total 32 bits, 5000Hz
- Can measure frequency from 0 to 1000Hz, the resolution is 0.1Hz
- Accept reed and hall sensor output from water meter or other meters
- Static and lightning protection for each input
- The input channel number is configurable, can be set up from 1 channel through 16 channels, improve frequency for small count input
- Surge-protected RS232/Rs485 ensure reliability
- A lot of spare FLASH can be used to store user’s parameters
- DIN support available
|
Price: $75
|
Price: $75
|
Technical_S6301.zip |
Technical_S6302.zip |
|
|
S6316: Ethernet 16 channels normal open relay output, Modbus/TCPIP protocol and Modbus protocol |
S6889: Ethernet to RS232/RS485 converter, Modbus TCP IP to Modbus rtu converter |
- Industry Ethernet with MODBUS/TCPIP
- RS485 with MODBUS protocol to configure the module
- A lot of spare FLASH can be used to store user’s parameters
- DIN rail support available
|
- Industry Ethernet with MODBUS/TCPIP protocol
- RS232, RS485 with MODBUS protocol
- Rs485 port can attach 254 slave RS485 device
- A lot of RAM/ROM can use to add more features
- Can update firmware through RS23 port by user
- LEDs indicate each port and system work status
- Integrate clock can do some schedule according to user requirement
- DIN rail support available
|
Price: $95
|
Price: $100
|
Technical_S6316.zip |
Technical_S6889.zip |
S6316C :Ethernet 16 channels normal CLOSE relay output, Modbus/TCPIP protocol.$99
|
S6887:,Ethernet to RS485 converter,no protocol limitation.$80
|
|
|
S6303 : Ethernet digital output modules,16 channels isolated digital output, Modbus/TCPIP protocol and Modbus protocol |
S6305 : 5 channels power relay output modules |
-
S6303 Ethernet digital output module has total 16 channels isolated open-collector output, S6303 can connect to PC through RS232 or RS485 port, default is RS485,serial port support modbus protocol, and connect to local Ethernet with modbus/tcpip protocol. All these communication port has static, over current, over voltage protect.
-
Isolated open-collector output can drive power relay directly
-
Industry Ethernet with MODBUS/TCPIP
-
RS232 / RS485 with MODBUS protocol to configure the module
-
Surge-protected RS232/Rs485 ensure reliability
-
A lot of spare FLASH can be used to store user’s parameters
-
DIN support available
|
-
S6305 Ethernet power relay output module has total 5 channels relay normal open output. The contact can handle the max 12A@220VAC.Output, S6305 can connect to PC through RS232 or RS485 port, default is RS485, serial port support modbus protocol, and connect to local Ethernet with modbus/tcpip protocol. All these communication port has static, over current, over voltage protect. The max current can up to12A@220VAC, 5 channels in very low price
- Industry Ethernet with MODBUS/TCPIP
- RS232 / RS485 with MODBUS protocol to configure the module
- Surge-protected RS232/Rs485 ensure reliability
- A lot of spare FLASH can be used to store user’s parameters
- DIN support available
|
Price: $79.99
|
Price: $79.99
|
Technical_S6303.zip |
Technical_S6305.zip |
TCPIP_wriring1 |
TCPIP_wriring1 |
TCPIP_wriring2 |
TCPIP_wriring2 |
|
- Auto detected 10/100M High speed Ethernet
- AUTO MDI/MDIX, Use crossover cable or parallel cable connection
- Baud rate 300 ~ 25600 bps
- TCP Server, TCP Client, UDP client , UDP server
- Can work as Virtual COM
- Auto reconnect TCP connection
- Socket program reference
- Free setup software and setup Agreement available
- Agreement: ETHERNET, ARP, IP, UDP, TCP
- 3.3V or 5V two power input interface
- OEM and custom versions available
|
Price: $17.99 |
Technical_S6000.zip |
Related Ethernet IO modules |
S6716: Ethernet 16 chananels analog input modules 0-50mV,0-100mV,0-150mV,0-200mV,0-500mV inputs ,12-bit ADCs, Modbus/TCPIP and Modbus protocol $115USD
|
S6816: Ethernet 16 chananels analog input modules 0-50mV,0-100mV,0-150mV,0-200mV,0-500mV inputs ,16-bit ADCs, Modbus/TCPIP and Modbus protoco l$120USD
|
|
|
|
|