S5000 Series
|
|
S5102 : 8 -CH 0- 5V,0 -10V,4 - 20mA analog inputs,6-CH isolated DI, 12-CH relay outputs , 2-CH 0-10V analog output module |
S5140 : 40 channels 0- 5V,4 - 20mA,10K NTC thermistor,dry contact analog inputs module |
- Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- The channel number is configurable, can be set up from 1 channel through 8 channels, for analog input and set up from 1 to 6 for digital input, improve sample rate for small count input
- 2 channels 0-10V analog output with high accurate reference chip
- Isolated digital inputs can be configured as counter input, total 32 bits,1000Hz
- Total 12 channels relay output,mormal open contact
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- White and black encloure available ,DIN rail
|
- Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- Surge-protected and isolated Rs485 ensure reliability
- The channel number is configurable, can be set up from 1channel through 40 channels, improve sample rate for small count analog input
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- White and black encloure available ,DIN rail
|
Technical_S5102.zip |
Technical_S5140.zip |
Price: $109
|
Price: $89
|
|
|
S5301 : 24 channels isolated digtial input and 16 channels open-collector digtial output module |
S5302 : 40 channels isolated DRY/WET contact digital input module |
- Isolated digital inputs can be configured as counter input, total 32 bits,5000Hz
- Can measure frequency from 0 to 1000Hz,the resolution is 0.1Hz
- Accept reed and hall sensor output from water meter or other meters
- Static and lightning protection for each input
- The input channel number is configurable, can be set up from 1 channel through 24 channels, improve frequency for small count input
- Isolated open-collector output can drive power relay directly
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- White and black encloure available ,DIN rail
|
- Isolated digital inputs can be configured as counter input, total 32 bits,5000Hz
- Can measure frequency from 0 to 1000Hz,the resolution is 0.1Hz
- Accept reed and hall sensor output from water meter or other meters
- Static and lightning protection for each input
- The input channel number is configurable, can be set up from 1 channel through 40 channels, improve frequency for small count input
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- White and black encloure available ,DIN rail
|
Technical_S5301.zip |
Technical_S5302.zip |
Price: $89
|
Price: $89
|
|
|
S5100 : 8 channels 0- 5V,0 -10V,4 - 20mA analog inputs,10 relay outputs ,12bits ADC |
S5200 : 8 channels 0- 5V,0 -10V,4 - 20mA analog inputs,10 relay outputs ,16 bits ADC |
- Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- 10 channel normal open relay outputs, each output channel can be set AUTO/OFF/HAND by a 3-states switch
- Surge-protected and isolated Rs485 ensure reliability
- The channel number is configurable, can be set up from one channel through eight channels, improve sample rate for small count analog input
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- White and black encloure available
|
- Surge-protected analog inputs with 16-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- 10 channel normal open relay outputs, each output channel can be set AUTO/OFF/HAND by a 3-states switch
- Surge-protected and isolated Rs485 ensure reliability
- The channel number is configurable, can be set up from one channel through eight channels, improve sample rate for small count analog input
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- White and black encloure available
|
Technical_S5100.zip |
Technical_S5200.zip |
Modbus_Protocol.pdf |
Modbus_Protocol.pdf |
Price: $115
|
Price: $123
|
|
|
S5116 : 16 channels 0- 5V,0 -10V,4 - 20mA analog inputs,4 relay outputs ,12bits ADC |
S5132A :32 channels 0- 5V ,dry contact,NTC 10 K thermistor inputs |
- Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- 4channel normal open relay outputs, each output channel can be set AUTO/OFF/HAND by a 3-states switch
- Surge-protected and isolated Rs485 ensure reliability
- The channel number is configurable, can be set up from one channel through eight channels, improve sample rate for small count analog input
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- White and black encloure available
|
- Surge-protected analog inputs with 16-bit resolution and 100k sample speed
- Input can be any combination of 0-5V,NTC 10K thermistor and dry contact
- Surge-protected and isolated Rs485 ensure reliability
- The channel number is configurable, can be set up from one channel through eight channels, improve sample rate for small count analog input
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- White and black encloure available
- Related products:S5132B,32 channels 0-10v input
- Related products:S5132C ,32 channels 4-20mA input
|
Technical_S5116.zip |
Technical_S5132A.zip |
Modbus_Protocol.pdf |
Modbus_Protocol.pdf |
Price: $115
|
Price: $100
|
S3000 series
|
|
S3100 : 8 channels 0- 5V,0 -10V,4 - 20mA analog inputs, 12bits ADC |
S3200 : 8 channels 0- 5V,0 -10V,4 - 20mA analog inputs, 16bits ADC |
- Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- Surge-protected and isolated Rs485 ensure reliability
- The channel number is configurable, can be set up from one channel through 8 channel,improve sample rate for small count analog input
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- Can detect RS232 or RS485 automatically ,no need jumper
|
- Surge-protected analog inputs with 16-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- Surge-protected and isolated Rs485 ensure reliability
- The channel number is configurable, can be set up from one channel through 8 channel,improve sample rate for small count analog input
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- Can detect RS232 or RS485 automatically ,no need jumper
|
|
|
Price: $71
|
Price: $80
|
|
|
S3101: 12 channels 0-5V,NTC 10K thermistor,dry contact inputs,12Bits,100K ADC |
S3102: 12 channels 0-10V inputs,12Bits,100K ADC |
1. Surge-protected analog inputs with 12-bit resolution and 100k sample speed
2.
Input can be any combination of,0-5V,NTC 10K thermistor and dry contact
3.
Surge-protected Rs485 ensure reliability
4.
The channel number is configurable, can be set up from 1 channel through 12 channel, improve sample rate for small count analog input
5.
Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
6.
You can tell us your requirement. we will update our firmware even after you received the modules ,you can update your modules through ISP. |
1. Surge-protected analog inputs with 12-bit resolution and 100k sample speed
2.
Input is 0-10V,fixed
3.
Surge-protected Rs485 ensure reliability
4.
The channel number is configurable, can be set up from 1 channel through 12 channel, improve sample rate for small count analog input
5.
Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
6.
You can tell us your requirement. we will update our firmware even after you received the modules ,you can update your modules through ISP.
7.This product support any combination of input,such as 4 channels dry contact input + 4 channels NTC input + 4 channels 0-32VDC input
or 2 channels 0-20mA input + 10 channels 0-24VDC input etc.
|
Price: $53
|
Price: $53
|
Technical_S3101.zip |
Technical_S3102.zip |
S3201: 12 channels 0-5V,NTC 10K thermistor,dry contact inputs,16Bits,100K ADC 55USD
|
S3202: 12 channels 0-10V,16Bits,100K ADC 55USD
|
S3105: 16 channels 0-5V,NTC 10K thermistor,dry contact inputs,12Bits,100K ADC 58USD
|
S3106: 16 channels 0-10V,12Bits,100K ADC 58USD
|
S3205: 16 channels 0-5V,NTC 10K thermistor,dry contact inputs,16Bits,100K ADC 66USD
|
S3206: 16 channels 0-10V,16Bits,100K ADC 66USD
|
|
|
S3103: 12 channels4-20mA inputs,12Bits,100K ADC |
S3301: 8 dry/wet contact inputs,6 open-collector outputs |
1. Surge-protected analog inputs with 12-bit resolution and 100k sample speed
2.
Input is 4-20mA,fixed
3.
Surge-protected Rs485 ensure reliability
4.
The channel number is configurable, can be set up from 1 channel through 12 channel, improve sample rate for small count analog input
5.
Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
6.
You can tell us your requirement. we will update our firmware even after you received the modules ,you can update your modules through ISP |
1. Isolated digital inputs can be configured as 32-bit counter input
2.
Static ,lightning protection for each input
3.
The input channel number is configurable, can be set up from 1 channel through 8 channels, improve frequency for small count input
4.
Isolated open-collector output can drive power relay directly
5.
Surge-protected and isolated Rs485 ensure reliability
6.
Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
7.
You can tell us your requirement. we will update our firmware even after you received the modules ,you can update your modules via ISP through RS485 BUS |
Price: $53
|
Price: $55
|
Technical_S3103.zip |
Technical_S3301.zip |
S3203: 12 channels4-20mA inputs,16Bits,100K ADC 55USD |
|
S3107: 16 channels4-20mA inputs,12Bits,100K ADC 58USD |
|
|
|
S3302 : 16 isolated dry/wet contact inputs |
S3306:16 isolated 0 to 36VDCdigital inputs |
1. Isolated digital inputs can be configured as 32-bit counter input
2. 32-bit counter be stored into FLASH when power off
3. Can measue frequency from 0 to 200Hz,the resolution is 0.1Hz
4. Static and lightning protection for each input
5. Accept dry contact,open-collector,TTL and wet contact input
6. The input channel number is configurable, can be set up from 1 channel through 16 channels, improve frequency for small count input
7. Surge-protected and isolated Rs485 ensure reliabilityStandard ModBus protocol allows for up to 254 unique devices on one RS485 network
8. You can tell us your requirement. we will update our firmware even after you received the modules ,you can update your modules via ISP through RS485 BUS. |
1. Isolated digital inputs can be configured as counter input, total 32 bits
2. 32-bit counter be stored into FLASH when power off
3. Can measue frequency from 0 to 200Hz,the resolution is 0.1Hz
4.
Static and lightning protection for each input
5.
The input channel number is configurable, can be set up from 1 channel through 16 channels, improve frequency for small count input
6.
Surge-protected and isolated Rs485 ensure reliability
7.
Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
8.
You can tell us your requirement. we will update our firmware even after you received the modules ,you can update your modules via ISP through RS485 BUS. |
Technical_S3302.zip |
Technical_S3306.zip |
Price: $55
|
Price: $59.99
|
|
|
S3303 :16 isolated open-collector outputs |
S3303E :16 isolated open-collector outputs |
- Isolated open-collector output can drive power relay directly
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- The maximum output current can up to 40mA
|
- Isolated open-collector output can drive power relay directly
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- The output current can up to 200mA
|
Technical_S3303.zip |
Technical_S3303E.zip |
Price: $59.99
|
Price: $58
|
|
|
S3305 : 5 Channels Power Relay Output,normal open |
S3401: 1 channel analog output ,12-bit DAC |
- The max current can up to 3A@220VAC, 5 channels in very low price
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
|
- Multiple output range setting, 0-10V,0-5V,0-20mA,4-20mA
- The analog output can be read back
- Jumper to select external power for current output for big load
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
|
Technical_S3305.zip |
Technical_S3401.zip |
Price: $59.99
|
Price: $85
|
|
|
S3402: 2 channels analog output ,12-bit DAC |
S3600: 4 channels 3-wire RTD input,RS485 ,MODBUS/RTU,MODBUS/ASCII |
- Multiple output range setting, 0-10V,0-5V,0-20mA,4-20mA
- The analog output can be read back
- Jumper to select external power for current output for big load
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
|
- Surge-protected RTD inputs with 16-bit resolution and 100k sample speed
- 3-Wire to avoid resistance affect accuracy
- Different RTD sensor available
- Different temperature range available
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- Can update your firmware via ISP through RS485 network
|
Technical_S3402.zip |
Technical_S3600.zip |
Modbus_Protocol.pdf |
Modbus_Protocol.pdf |
Price: $95
|
Price: $69
|
|
|
S3400S: 4 channels analog output ,voltage read back,12-bit DAC |
S3408 : 8 channels analog output ,voltage from0 to 10V,12-bit DAC |
1. Multiple output range setting,0-10V,0-5V,0-20mA,4-20mA
2. Surge-protected and isolated Rs485 ensure reliability
3.
Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
4.
You can tell us your requirement. we will update our firmware even after you received the modules ,you can update your modules via ISP through RS485 BUS |
1. Multiple output channels ,output voltage range is 0-10V
2. Surge-protected and isolated Rs485 ensure reliability
3.
Standard ModBus RTU protocol allows for up to 254 unique devices on one RS485 network
4.
You can tell us your requirement. we will update our firmware even after you received the modules ,you can update your modules via ISP through RS485 BUS |
Technical_S3400S.zip |
Technical_S3408.zip |
|
|
Price: $135
|
Price: $89
|
|
|
|
|