S5134 : 8 -CH 0- 5V,0 -10V,4 - 20mA analog inputs,3-CH isolated DI, 8-CH isolated open-collector outputs , 8-CH 0-10V analog output module ,Ethernet/RS485,Modbus TCPIP/Modbus protocol

S5138 : 8 -CH 0- 5V,0 -10V,4 - 20mA analog inputs,6-CH isolated DI, 16-CH isolated open-collector outputs ,,Ethernet/RS485,Modbus TCPIP/Modbus protocol
  1. Surge-protected analog inputs with 12-bit resolution and 100k sample speed
  2. Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
  3. The channel number is configurable, can be set up from 1 channel through 8 channels, for analog input and set up from 1 to 3 for digital input, improve sample rate for small count input
  4. 8 channels 0-10V analog output with high accurate reference chip
  5. 3 channels Isolated digital inputs can be configured as counter input, total 32 bits,1000Hz
  6. Total 8 channels isolated open-collector output
  7. Standard ModBus TCPIP protocol,easy work with PLC
  8. Surge-protected and isolated Rs485 ensure reliability
  9. Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
  10. A lot of spare FLASH can be used to store user’s parameters
  11. White and black encloure available ,DIN rail
  12. CE & RoHS
  1. Surge-protected analog inputs with 12-bit resolution and 100k sample speed
  2. Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
  3. The channel number is configurable, can be set up from 1 channel through 8 channels, for analog input and set up from 1 to 6 for digital input, improve sample rate for small count input
  4. 6 channels Isolated digital inputs can be configured as counter input, total 32 bits,1000Hz
  5. Total 16 channels isolated open-collector output
  6. Standard ModBus TCPIP protocol,easy work with PLC
  7. Surge-protected and isolated Rs485 ensure reliability
  8. Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
  9. A lot of spare FLASH can be used to store user’s parameters
  10. White and black encloure available ,DIN rail
  11. CE & RoHS
Technical_S5134.zip Technical_S5138.zip
Price: $145
Price: $115

RS485 Modules <-- > More

RS485 Modules <-- > More

S5102 : 8 -CH 0- 5V,0 -10V,4 - 20mA analog inputs,6-CH isolated DI, 12-CH relay outputs , 2-CH 0-10V analog output module

S5140 : 40 channels 0- 5V,4 - 20mA,10K NTC thermistor,dry contact analog inputs module
  1. Surge-protected analog inputs with 12-bit resolution and 100k sample speed
  2. Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
  3. The channel number is configurable, can be set up from 1 channel through 8 channels, for analog input and set up from 1 to 6 for digital input, improve sample rate for small count input
  4. 2 channels 0-10V analog output with high accurate reference chip
  5. Isolated digital inputs can be configured as counter input, total 32 bits,1000Hz
  6. Total 12 channels relay output,mormal open contact
  7. Surge-protected and isolated Rs485 ensure reliability
  8. Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
  9. A lot of spare FLASH can be used to store user’s parameters
  10. White and black encloure available ,DIN rail
  11. CE & RoHS
  1. Surge-protected analog inputs with 12-bit resolution and 100k sample speed
  2. Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
  3. Surge-protected and isolated Rs485 ensure reliability
  4. The channel number is configurable, can be set up from 1channel through 40 channels, improve sample rate for small count analog input
  5. Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
  6. A lot of spare FLASH can be used to store user’s parameters
  7. White and black encloure available ,DIN rail
  8. CE & RoHS
Technical_S5102.zip Technical_S5140.zip
Price: $109
Price: $89

HOT ITEM

HOT ITEM

S5301 : 24 channels isolated digtial input and 16 channels open-collector digtial output module S5302 : 40 channels isolated DRY/WET contact digital input module
  1. Isolated digital inputs can be configured as counter input, total 32 bits,5000Hz
  2. Can measure frequency from 0 to 1000Hz,the resolution is 0.1Hz
  3. Accept reed and hall sensor output from water meter or other meters
  4. Static and lightning protection for each input
  5. The input channel number is configurable, can be set up from 1 channel through 24 channels, improve frequency for small count input
  6. Isolated open-collector output can drive power relay directly
  7. Surge-protected and isolated Rs485 ensure reliability
  8. Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
  9. A lot of spare FLASH can be used to store user’s parameters
  10. White and black encloure available ,DIN rail
  11. CE & RoHS
  1. Isolated digital inputs can be configured as counter input, total 32 bits,5000Hz
  2. Can measure frequency from 0 to 1000Hz,the resolution is 0.1Hz
  3. Accept reed and hall sensor output from water meter or other meters
  4. Static and lightning protection for each input
  5. The input channel number is configurable, can be set up from 1 channel through 40 channels, improve frequency for small count input
  6. Surge-protected and isolated Rs485 ensure reliability
  7. Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
  8. A lot of spare FLASH can be used to store user’s parameters
  9. White and black encloure available ,DIN rail
  10. CE & RoHS
Technical_S5301.zip Technical_S5302.zip
Price: $89
Price: $89

RS485 Modules <-- > More

Ethernet Modules <-- > More

S5100 : 8 channels 0- 5V,0 -10V,4 - 20mA analog inputs,10 relay outputs ,12bits ADC S6116: Ethernet 16 chananels analog input modules 0-5V, 0-10V, 4-20mA, dry contact, 10K NTC thermistor inputs ,12-bit ADCs, Modbus/TCPIP and Modbus protocol
  1. Surge-protected analog inputs with 12-bit resolution and 100k sample speed
  2. Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
  3. 10 channel normal open relay outputs, each output channel can be set AUTO/OFF/HAND by a 3-states switch
  4. Surge-protected and isolated Rs485 ensure reliability
  5. The channel number is configurable, can be set up from one channel through eight channels, improve sample rate for small count analog input
  6. Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
  7. White and black encloure available
  8. CE & RoHS
  1. Surge-protected analog inputs with 12-bit resolution and 100k sample speed
  2. Input can be any combination of 0-10V, 0-5V, 4-20mA, NTC 10K thermistor and dry contact
  3. The channel number is configurable, can be set up from one channel through eight channels, improve sample rate for small count analog input
  4. A lot of spare FLASH can be used to store user’s parameters
  5. Standard MODBUS/TCPIP protocol for Ethernet and standard MODBUS protocol for RS485
  6. DIN support available
  7. CE & RoHS
Technical_S5100.zip Technical_S6116.zip
Modbus_Protocol.pdf Modbus_Protocol.pdf
Price: $115
Price: $80

Zigbee Modules <-- > More

RTD Modules

S7106: 4 channels 0- 5V, 0 -10V, 4 - 20mA analog inputs,
12bits ADC,2 channels relay output(220VAC/3A) Modbus RTU/ASCII, Zigbee wireless
S3600: 4 channels 3-wire RTD input,RS485 ,MODBUS/RTU,MODBUS/ASCII
  1. Surge-protected analog inputs with 12-bit resolution and 100k
    sample speed
  2. Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K
    thermistor and dry contact
  3. Accept 0-50Hz pulse input and store pulse counter in Flash
  4. 2 channesl relay output (220VAC/3A) and 1channel 0-5V analog output
  5. Can measure the power supply voltage
  6. Reliable Zigbee can up to 2000 meters communication
  7. The channel number is configurable, can be set up from 1 channel
    through 4 channel, improve sample rate for small count analog input
  8. Standard ModBus protocol allows for up to 254 unique devices on
    one network
  9. A lot of spare FLASH can be used to store user’s parameters
  10. Can detect RS232 or ZIGBEE automatically, no need jumper
  11. You can tell us your requirement. we will update our firmware
    even after you received the modules ,you can update your modules
    through ISP.
  1. Surge-protected RTD inputs with 16-bit resolution and 100k sample speed
  2. 3-Wire to avoid resistance affect accuracy
  3. Different RTD sensor available
  4. Different temperature range available
  5. Surge-protected and isolated Rs485 ensure reliability
  6. Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
  7. A lot of spare FLASH can be used to store user’s parameters
  8. Can update your firmware via ISP through RS485 network
  9. CE & RoHS
Technical_S7106.zip Technical_S3600.zip
Modbus_Protocol.pdf Modbus_Protocol.pdf
Price: $100
Price: $69

H5104:16 channels 0-10V,4-20mA,10K NTC thermistor analog input, 4 channels 0-10V analog output,12 bit ADC,DAC.

12 channels isolated digital input and 12 channels relay output ,MODBUS RS485

S5608:8 channels 0-10V,4-20mA,10K NTC thermistor analog input, 8 channels 0-10V analog output,12 bit ADC,DAC 20 channels isolated digital input,MODBUS RS485
    1. Surge-protected analog inputs with 12-bit resolution and 100k sample speed
    2. Input can be any combination of4-20mA,0-10V,NTC 10K thermistor, open-collector and dry contact
    3. The channel number is configurable, can be set up from 1 channel through 16 channels.
    4. 4 channels 0-10V analog output with high accurate reference chip and 12 bit resolution
    5. Isolated digital inputs can be configured as counter input, total 32 bits,1000Hz
    6. Total 12 channels relay output,mormal open contact
    7. Surge-protected and isolated Rs485 ensure reliability
    8. Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
    9. A lot of spare FLASH can be used to store user’s parameters
    10. Can update your firmware via ISP through RS485 network, can provide any hex file to help you finish some logic control
  1. Surge-protected analog inputs with 12-bit resolution and total 8 universal analog input
  2. Input can be any combination of 0-5V,4-20mA,0-10V,NTC 10K thermistor, open-collector and dry contact
  3. The channel number is configurable, can be set up from 1 channel through 8 channels, for analog input and set up from 1 to 20 for digital input, improve sample rate for small count input
  4. 8 channels 0-10V analog output with high accurate reference chip
  5. Isolated digital inputs can be configured as counter input, total 32 bits,1000Hz
  6. Standard ModBus RTUprotocol,easy work with PLC
  7. Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
  8. A lot of spare FLASH can be used to store user’s parameters
  9. Can update your firmware via ISP through RS485 network, can provide any hex file to help you finish some logic control
  10. DIN support available
Technical_H5104.zip Technical_S5608.zip
Price:$149
Price:$125